Protocontrol offers Belt Sway Switches in flameproof housing for use in hazardous areas.Belt swy switch allows smooth running of the conveyer and protects it from damages by over swaying which can occur due to uneven loading of material, worn out idler roller bearings etc. The belt sway is generally mounted on both sides and near the edge of conveyer belt. A small gap is provided between contact roller and the belt edge to allow normal running of the belt with acceptable tolerance. When swaying exceeds normal limit, the belt edge pushes the contact roller, which drives the switch and operates the contacts. Switch resets automatically when the belt resumes normal running.
Enclosure Flameproof, Cast Al, LM6 or Cast Iron certified by compitant authority, IP 65
Following models are available
BS 101 F Belt Sway Switch with 1 NO + 1 NC contact, flameproof enclosure
BS 202 F Belt Sway Switch with 2 NO + 2 NC contact , Flameproof enclosure
Additional Information:
Production Capacity: 200 per week
Delivery Time: 2-3 Weeks
Packaging Details: Industrial worthy
Kami adalah agen tunggal untuk alat industri merk Kansai Automation dari Jepang dan Cambridge Sensotec Gas Analyzer dari Inggris. Selain itu, kami adalah importir umum semua alat industri disesuaikan dengan kebutuhan end user. Hubungi kami di syukur1970@gmail.com
Penayangan bulan lalu
Minggu, 26 April 2020
Protocontrol Flameproof Model Belt Sway Switch
Protocontrol offers Belt Sway Switches in flameproof housing for use in hazardous areas.Belt swy switch allows smooth running of the conveyer and protects it from damages by over swaying which can occur due to uneven loading of material, worn out idler roller bearings etc. The belt sway is generally mounted on both sides and near the edge of conveyer belt. A small gap is provided between contact roller and the belt edge to allow normal running of the belt with acceptable tolerance. When swaying exceeds normal limit, the belt edge pushes the contact roller, which drives the switch and operates the contacts. Switch resets automatically when the belt resumes normal running.
Enclosure Flameproof, Cast Al, LM6 or Cast Iron certified by compitant authority, IP 65
Following models are available
BS 101 F Belt Sway Switch with 1 NO + 1 NC contact, flameproof enclosure
BS 202 F Belt Sway Switch with 2 NO + 2 NC contact , Flameproof enclosure
Additional Information:
Production Capacity: 200 per week
Delivery Time: 2-3 Weeks
Packaging Details: Industrial worthy
Walchem WCT/WDT400 Cooling Tower Controllers
WCT/WDT400 Cooling Tower Controllers
Cooling,Tower,Controllers,WCT,WDT,400,Walchem,CorporationThe WCT/WDT400 Cooling Tower Controllers represent the latest in technological and innovative advancements from Walchem. All of the standard features you'd expect from a conventional cooling tower controller are included, plus optional simple-to-use information management tools that enable water treatment professionals to deliver more effective service to their customers.
Coling,Tower,Controllers,WCT,WDT,400,Walchem,CorporationThe WCT/WDT400 Controllers have the ability to store sensor and temperature values, water usage, relay status, and user settings. A USB memory stick is all that's needed to extract the information. Download logs from the USB stick to a PC at your convenience, or copy your preferred treatment program settings to another controller to speed start-up. It couldn't be easier!
WECT/EDT Controllers include an electrodeless conductivity sensor that's impervious to contamination by oils, scale, biofilm or other coatings, resulting in a low maintenance system that provides reliable effective control.
Key Benefits:
Ensure Optimal Performance and Maximum Efficiency
Precise control of conductivity and chemical feed reduces water consumption and inhibits corrosion, solids precipitation, scale build-up and growth of algae or dangerous bacteria.
More Informative Monthly Reports
Download stored data from the controller to a USB flash stick. Use the data to easily develop reports that show actual water usage, system conductivity, temperature and more.
Efficient Customer Service
Quickly identify system upsets by knowing exactly what happened and when. An event log can be downloaded to tell you precisely when pumps turned on, valves opened and when there was flow or no-flow.
Validation and Verification Made Easy
Use stored data from the controller to simply and easily validate water treatment results. The data and event logs show water usage, system conductivity and temperature, as well as accumulated chemical feed and bleed times.
Save Time
Copy the user settings from your controller to a USB flash stick and upload to a new controller. Programming your new controller this way can be accomplished in seconds. It's that simple!
Torontech Vicat Apparatus
ASTM C 187- 191
Vicat Apparatus is designed to determine the initial and final setting time of cement and mortar paste.
Standard Configuration:
Vicat Apparatus comes complete with:
Initial-set needle, 1.0 mm dia
Consistency plunger 10 mm dia
Vicat mould 60/70 dia. X 40mm
Glass plate and thermometer
Dimensions (wxdxh): 150x220x440 mm
Weight: 3.5 kg
Modified Vicat Apparatus
Modified Vicat Apparatus is designed for testing of gypsum and monitoring of plaster paste, with additional weight 1000g for obtaining a total mass of all moving parts of 1115g.
Standard Configuration:
Modified Vicat Apparatus comes complete with:
2 x conical plungers, 8 mm dia
2 x Plexiglas plates 108 x 108 x 6 mm
2 x Vicat moulds 65é75 mm dia
Conical plunger + weight = 115 g Mass of the moving parts
Supplementary weight: 1 kg including tripping device
Dimensions (wxdxh): 150x220x440 mm
Weight: 3.3 kg
Gilson Asphalt Electric Core Drill
Electric Core Drill is a versatile coring system for a wide range of concrete and asphalt sampling applications. The rugged, economical drill has a powerful two-speed electric motor and bit capacities up to 12in (305mm) diameter. Its column rotates 180° horizontally allowing precise placement of the drill bit. The super-duty two-speed (450/900rpm) 3.5hp motor and carriage can be removed or reattached without changing location for ease in snapping cores and adding extension rods. The 10in (254mm) wide-wheeled base with vacuum/anchor and leveling feet securely anchors the drill to a smooth pavement or floor. Large 6in wheels allow easy mobility. The drill comes with a water swivel, vacuum pump, filter, hose and quick connections.
Features:
Rotating column for precise placement of drill bit
Super-duty two-speed (450/900rpm) 3.5hp motor and carriage are easily removable
Securely anchors to a smooth pavement or floor
Included Items:
Electric Core Drill
Vacuum Base and mounting column
Water Swivel
Oilless vacuum pump with filter, hose and quick connections
Accessories:
CDA-15 Core Retrieval Tongs for removing 4 or 6in cores from asphalt or concrete surface
CDA-22 Water Recirculator with trap-ring and electric pump for recirculation of drilling water
CDA-20 4gal Pressurized Water Tank is a manually-pressurized portable water tank
CDA-32 Replacement Vacuum Gasket is replacement piece with mastic for the core drill’s vacuum base
CDA-24 9in Extension Rod easily attaches for deeper drilling
CDA-26 18in Drilling Strap Wrench for effortless, damage-free attachment and removal of coring bits
Asphalt Coring Bits
Concrete Coring Bits
ABM VAN ZIJL VICAMATIC 2 automatic vicat apparatus
EN 196-3 | EN 480-2 | ASTM C191 | AASHTO T131
Automatic vicat apparatus, for determining automatically the setting time and consistency of cement. CONTROLS has a long tradition in manufacturing automatic setting time testers for cement and mortar. A new generation, the third one, is now available. The new machine has been completely redesigned based on the innovative CVI-TECH philosophy. As with the older generations the test procedure is unchanged, a needle (or a probe) drops freely into a cement sample at regular intervals and in fixed positions. Penetration depth is measured by a sensor with 0,1 mm resolution. Along with hardening process development the penetration depth decreases, when it matches some thresholds pre-defined by Standards initial and final setting times are measured and recorded.
Specifications
Large size 4,3'' touch screen color display
LAN port for direct connection to PC of a single unit or connection to a LAN hub for creating a network with up to 32 independent units all controlled by a single PC. 1 LAN cable is included
USB port for data storage on pen-drive (included)
Test procedures can be customized and stored to match user-defined requirements
Can incorporate an integrated graphic printer showing test result and setting time plot
Large test space with easy accessibility
Automatic calculation of initial and final setting time at programmable penetration depth limits
Wide range of accessories including EN and ASTM/AASHTO parts, in-water testing kit, needle cleaning device, integrated printer, probes for testing consistency and gypsum
Minimum penetrations rate: 10 seconds
Penetration measurement by encoder
Besmak Vicat Apparatus
MANUAL TYPE
Used for determination of setting time and consistency of cement. Mould, Beginning, Ending and water content needles are included.
AUTOMATIC TYPE
The Vicat apparatus, that is designed and manufactured using the most recent and sophisticated technology, is used for the initial and fi nal setting time determination of cements or mortar pastes.
The unit is manufactured with anticorrosion and tropicalized components to be used in places with humidity not below 90% and 20°C. controlled temperature as required by EN Specifi cations.
The entire test is made in a fully automatic way and gives a very precise and repeatable result. The results are printed on the incorporated printer and this eliminates the manual operations of installing and zeroing the paper graph on the drum.
Fitok Pressure Gauge GA-63-NS4-4000PB
Frer Earth Leakage Relay
The X...DL3 series earth leakage relays are designed to measure the leakage or unbalanced currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching o the power supply to the defective system. Thanks to their distinctive feature (the displaying of the leakage current) it is possible to continuously monitor the insulation state and to program the preventive maintenance in order to avoid unexpected power breaks.
Main functions:
- Continuous digital indication of the leakage current
- Logic Selectivity - Automati retry
- Internal clock and storage of the last 10 events
- RS485 Modbus RTU, measurements, event archive, scope
- Selectable antibrillation lter
- Storing of the intervention current values
- Measure and display of the THD
- Selectable 3rd harmonic lter
- AC measurements up to 10kHz
Thermo Fisher Scientific High Performance Benchtop Centrifuges
Choose from a growing family of benchtop centrifuges designed to meet the needs of your specific applications. With careful attention to your space, process and protocol requirements, we continue to innovate our line of centrifuges that stand out for their performance, reliability, consistency and safety. Whether performing clinical protocols, cell culture procedures, microplate processing, or anything in between, Thermo Scientific centrifuges fulfill a variety of separation needs.
Ideal for research or controlled environments, our high performance benchtop centrifuges meet customers' needs for application flexibility and high speeds. They come in medium 1.6L and large 4L sizes with touch screen options and floor/portable options, offering a high performing drive with an advanced touch screen interface designed for maximum protocol versatility, complementing the numerous rotor configurations available.
Get unparalleled processing performance, maximum versatility, and exceptional energy efficiency with our high performance benchtop centrifuges.
Clark-Reliance Corporation - Anderson® - Centrifugal Separators
ANDERSON® SEPARATOR was founded in 1855 by a 25-year-old boilermaker named Valerius D. Anderson. He designed a very efficient steam cleaning and purification process for steam boilers. This centrifugal separator quickly became the industry standard for the removal of solids and liquids from steam. The new units quickly found applications in many other industries ranging from food processing to steel making. As Anderson Separator grew, so did its line of separation equipment. Anderson Separator became part of the Clark-Reliance family in the late 1980s and has continued to grow its business in the compressed air, steam, gas and power generation industries.
Principal of Operation
The Anderson Hi-eF™ Centrifugal Separators operate on a patented two-stage principle of separation that employs carefully controlled flow guiding the entrainment laden vapor through a series of vanes and baffles. Each component of the separating element is designed to obtain maximum separating efficiency. Briefly, in the first stage of the separation, impingement against a baffle removes the larger droplets of entrainment. In the second stage of separation, the separator removes the fine mist entrainment by utilizing centrifugal scrubbing action through a uniquely designed contact element. In each stage, the gas medium and the separated liquid are carefully and continuously guided for maximum efficiency. The separators are designed to handle large volume flow of a broad range of fluids. Self-cleaning and engineered without filters or moving parts, the separators are free from maintenance and repair.
Centrifugal Separators
ANDERSON's line of standard and custom centrifugal units are excellent for your air and steam separation needs.
Vertical Up Flow
In-Line
Exhaust Heads
Combination Separator Traps
Internal Steam Drum Purifiers
Multi-Stage and Single-Stage Designs
Available Models
Centrifugal Line Separators Large L, LS, LUS Centrifugal Separator with Coalescing Mesh CLL, CLI, CLU
Centrifugal Line Separators Small LC, LCF, LCR, LCC, LCCR Internal Centrifugal Separators IM, DIM, ID, DID
Centrifugal Receiver Separators LRH, LRV, LRU Internal Centrifugal Separators Steam Drum BI-6, BI-10
Centrifugal Separators TL, TLT, TLSX Exhaust Heads CEH, CEHF, EHF
BOECO Autoclave BTE-23D
BOECO Autoclave BTE-23D
BOECO Autoclave BTE-23D
(3)
Features:
Three times fractionated pre-vacuum
Stainless steel chamber
LCD display
Equipped with high quality and high performance pump
1 tray holder, 1 tray handle and 3 trays included
High quality water pump and valves
Independent steam generator
Two samples self-calibration
Overhead type water storage tank, easy to clean.
Drying procedure: Dry by vacuum.
Sterilization temperature: 121°C and 134°C
Test programs: Helix test, B&D test and Vacuum test.
Sterilization cycles:
9 cycles are available and 3 test programs.
It only have several buttons, very easy to use, any people can run it easily.
All cycles are fully automatic; there is no need for human intervention in cycle management.
Pressure protection locking system that ensures the door will not be opened once there is any pressure in chamber.
Sterilization documentation: Integrated Micro Printer and USB port to store
the information of the programme cycle in flash memory.
The sterilization time and dry time can be adjusted by manual, ensure user obtain best sterilization effects according to private requirements.
Malfunction detection system, corresponding error code will be showed on the display once there’s something goes wrong.
Safety:
Warning system prevents starting a cycle if door is not properly locked.
Triple Threat Protection for overheating and overpressure.
The pressure protection system will automatically cut off the electricity supply once the temperature of chamber inside is abnormally. Motorola pressure sensor is used to accurately sense the state of pressure inside chamber.
Temperature control system is using high quality PT1000 temperature sensor, it is high precision, reliable service and prompt measure, ensure accurate and timely transmission of temperature fluctuation.
The safety valve will release steam in case the pressure inside chamber exceed normal levels.
Technical Information:
Conform to CE and EN13060
Manufactured under ISO 9001 and ISO 13485 norms
Chamber Size: ø 247 x 460 mm (23 L)
External dimension: 690 x 480 x 455 mm, Netweight 51 kg
Packing box 750x560x460 mm, Grossweight 58 kg
Power: 220V, 50/60 Hz or 110V, 60HZ
Program Temperature Pressure Sterilization time Total time
SOLID 134 134°C 2.1 bar 4 min 25-45 min
SOLID 121 121°C 1.1 bar 20 min 35-60 min
LIQUID 134 134°C 2.1 bar 10 min 35-60 min
LIQUID 121 121 °C 1.1 bar 30 min 35-60 min
WRAPPED 134 134°C 2.1 bar 4 min 35-60 min
WRAPPED 121 121°C 1.1 bar 20 min 35-60 min
TEXTILE 134 (or wrapped) 134°C 2.1 bar 6 min 45-65 min
TEXTILE 121 (or wrapped) 121°C 1.1 bar 20 min 50-70 min
PRION 134°C 2.1 bar 18 min 45-70 min
B&D TEST 134°C 2.1 bar 3.5 min 15-20 min
Helix TEST 134°C 2.1 bar 3.5 min 22-35 min
Vacuum TEST - - - 15-20 min
Code Description
BOE 8902300 BOECO BTE-23D Bench Top Autoclave, Vol. 23 l. incl 1 tray holder, 1 tray handle and 3 trays,
micro printer and USB port, 220V, 50/60Hz
BOE 8902310 BOECO BTE-23D as above but for 110 V, 60 Hz
Wess Global Ultrasonic Sludge Density Meter (ENV200S)
The ENV200 is an ultrasonic instrument that measures the density of suspended solid in liquid. It comprises of sensors, a controller, and a junction box. ENV200 with PCM(Process Condition Monitoring) algorithm measures not only the size of received signal, which is often measured by conventional ultrasonic density meters but also observes changes in sound velocity and temperatures in the process. As it monitors operational status and water status in pipe and then decides the validity of each measurement, it contributes to increasing stability and reliability of the measurement. The ENV200 utilizes the EEA (Envelope Energy Average) method that saves reception signal envelop and then calculates its energy, rather than using the reception signal’s amplitude change. ENV200 offers three types of sensors, such as spool-piece, tank-mount, and Clamp-on type to accommodate all field demands at installation.
· • Continuous Measurement
• Process Monitoring Possible (Run, Stop, Full, Empty)
• 10,000 Points Data Logging & Trend Mode
• EEAM (Envelope Energy Average Method)
• Various Types of Sensors
• In-situ Measurement and Calibration
Koehler Instruments KV3000 and KV4000 Constant Temperature Kinematic Viscosity Baths
Test Method: Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.
Constant temperature bath with advanced temperature control circuitry and integrated timing features for convenient, accurate glass capillary viscometry determinations. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual digital displays permit easy setting and monitoring of bath temperature. Two place calibration offset capability is provided. Bath accommodates seven glass capillary viscometers of various types. Viewing the viscometers is made easy by glare-free LED illumination inside the bath and a baffle that provides a background for easy viewing. Temperature control uniformity is assured by means of motorized stirrer which provides complete circulation without turbulence. Connection of the built-in cooling coil to tap water or a recirculating water chiller facilitates temperature control at ambient or below ambient temperatures. Communications software (RS232, etc.) ramp-to-set, and other enhanced features are available at an additional cost.
Integrated Timing Features -The user can enter the viscosity constant for each viscometer on the front Touch Screen Control Panel, ans then get the test result in both efflux time and viscosity units automatically after stopping each timer. Timing function is displayed in 0.01 second resolution and is accurate within 0.01%.
Bath Construction and Safety Features - Bath chamber is a clear borosilicate glass vessel enclosed in a polyester-epoxy finished steel housing. Top working surface has seven 2" (51mm) viscometer ports. Front viewing window assures safe, distortion-free viewing. Microprocessor temperature controller incorporates safety circuitry that interrupts power to the heaters in the event of an overtemperature condition or disconnection of the primary probe. For added safety, an adjustable redundant controller with separate sensor probe interrupts power if an overtemperature situation occurs. An integrated low-liquid sensor prevents operation of the bath if the bath liquid is not filled to the proper level, and cuts off power should it fall below during operation. Both overtemperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed.
Shanghai Boqu DWS-51A Laboratory Sodium Meter
DWS-51A Laboratory Sodium Meter
DWS-51A is an intelligent laboratory Sodium meter. It is equipped with the dedicated laboratory PPb sodium ion measurement electrode and the reference electrode, with the static measurement performance in the beaker greatly improved, compares with the traditional sodium meters. As long as the user pays attention to the electrode cleaning, the satisfactory result can be achieved. It can be widely used for continuous monitoring of sodium ions of the solutions in thermal power plants, chemical fertilizer, metallurgy, environment protection, pharmaceutical industry, biochemical industry, foodstuff and running water.
Features
Double-row digital tube: To display μg/L, pNa/mV and temperature simultaneously.
Computer-based: Adopts high-performance CPU chip, high-precision AD conversion technology
to complete multi-parameter measurement and temperature compensation, with high precision and
good repeatability
High sensitivity: In the static water sample, it can detect 0.2ppb (8pNa)
Lasting stability: There is a very stable reading.
Technical Indexes
1.Display: Double-row digital tubes display displays Sodium ion concentration and temperature simultaneously.
2.Measuring range: 0.2 ug/L~23000mg/L
0.00 PNa~8.00 PNa.
-1000~ +1000 mV. 0~99.9℃
3.Resolution: 0.1 ug/L; 0 .1 mV, 0.1℃
4.Repeatability: reading ± 2.5%
5.Accuracy: reading ± 2.5%, ±0 .2 mV, ±0.3℃
6.Continuous stability time: >100 seconds
7.Detection lower limit: 0 .2 ug/L (8pNa)
8.Input impedance: >1012Ω
9.Temperature compensation range: automatic/manual 0 ~ 99.9 ℃,
10.Response speed: 32 seconds (25℃) or 50 seconds (15℃)
11.Communication interface: RS232
12.Power supply: AC 220V ± 22V, 50Hz ± 1Hz
13.Working conditions: ambient temperature: 0-60℃; relative humidity <≤90
14.Power-down memory: > 5 years
15.Calibration mode: One-point calibration, two-point calibration
Standard configuration
One secondary meter; one power supply; one reference electrode, one measuring electrode, one temperature
electrode; one set of electrode support
Bante Instruments - 931 Benchtop Sodium Ion Meter
Ion
Range
0.001~19999 (Deponding on the range of ISE)
Accuracy
±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Resolution
0.001, 0.01, 0.1, 1, automatic
Calibration Points
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Measurement Units
ppm, mg/L, mol/L or mmol/L
Temperature
Range
0~105°C, 32~221°F
Accuracy
±0.5°C, ±0.9°F
Resolution
0.1°C, 0.1°F
Offset Calibration
1 point
Calibration Range
Measured value ±10°C
General
Temperature Compensation
0~100°C, 32~212°F, manual or automatic
Stability Criteria
Low or high
Calibration Due Alarm
1 to 31 days or off
Memory
Stores up to 500 data sets
Output
USB communication interface
Connector
BNC
Display
6.5" custom LCD
Power
DC5V, using AC adapter, 220V/50Hz
Dimensions
210(L)×188(W)×60(H)mm
Weight
1.5kg
Scimatco SC5060 Polypropylene Acid Cabinet
Cabinet constructed of 3/8” polypropylene plastic
Cabinet marked ACID
All polypropylene door hinge, providing years of worry free service
Double doors with locks and keys
Excellent cabinet for very corrosive environments inside and out
Cabinet has a 2” liquid tight welded bottom to contain accidental spills
Meets OSHA standard for secondary containment
White in color
Aviteq Handling Technology
Bowl feeder - Sorting, dosing, storing
AViTEQ Bowl Feeders / Parts Conveyors for ordered arranging, individualizing and conveying are used in every case where mass parts have to be supplied to a magazine, a machine or to installation equipment, item for item, with a pre-determined orientation and time.
Advantages and benefits
High level of conveying capacity with compact dimensions
Operationally safe in continuous employment
Synchronized two-mass vibration system
No influencing of the vibration characteristics through the weight of the parts being conveyed
Maintenance-free drive
Conformity with all EC Guideline which affect the drives
Also available for explosion-endangered spaces (Ex), as well as for 60 Hz power systems and other mains voltages
Construction and operation mode
AViTEQ Bowl feeders / Parts conveyors are two-mass vibration systems, which are synchronized to be close to a resonant condition. The drive part includes the elements for vibration generation, such as electromagnet and leaf spring packages. The arrangement of the simple leaf springs determines the feed direction. Parts conveyors, which convey in clockwise direction, are designated with "R" (clockwise running). Parts conveyors which convey in anti-clockwise direction are designated with "L" (anti-clockwise running). In the case of an order, it is absolutely necessary that the feed direction be indicated. The pot is connected with the drive and is easily detachable. For individual itemization and alignment of parts, special mounted equipment (baffle plates) in the pot are necessary. Optimal design and coordination of the two-mass vibration system guarantee a uniform conveying action, which is also independent of the pot filling. The bowl feeder /parts conveyor is supported on rubber dampers. Vibrations are thus transmitted only weakly to the environment.
Accessories
Floor support and sound insulation hood
AViTEQ controller
Aviteq Conveyor Belt
Conveying guided arm troughs - Discharging, feeding, conveying
In many industrial production processes, sharp or hot waste bulk has to be handled (e.g. metal shavings, foundry sand or slugs). Often, it has to be transported over long distances underfloor before it will be disposed or re-processed. The use of conveyor belts often leads to difficulties due to high wear and overflowing of the floor trenches. The result: high maintenance costs, frequent cleaning of the ditches, thus interrupting production. The optimal solution for these tasks are our AViTEQ conveying guided arm troughs.
Advantages & Benefits
low height
transport of hoarse products
careful product transport
longer gutter trough
dust-proof design
Construction
The gutter trough is on trailing arms connected to a counter-vibration frame, this in turn is mounted on springs, this combination ensures that the dynamic forces are isolated up to 99 %. This allows frames and foundation are kept very small.
Selection
The dimensioning of the reversing conveyor depends on:
conveyed material
throughput
product size
height of the pits
length of the trail
Key figures
length: up to 22.000 mm
width: up to 900 mm
throughput: up to 180m³/h
drives: unbalanced motor, exciter, thrust crank
Aviteq UV Motor
Unbalance motor
Unbalance vibratory Motor, Unbalance vibrator motor, Unbalanced motor
AViTEQ Unbalance motors can be used as drives for almost each case of application in the vibration feeder technology and over all industries. Unbalanced motors are the prefered drive system, in particular if it depends on high throughput of bulk material.
Advantages and benefits
available as standard for explosion proofed ATEX zones 21+22
available as standard for CSA-apllication "Class 1 + 2"
available as standard with thermistor
operationally safe in continuous employment
high level of performance with compact dimensions
efficiency
latest state-of-the-art of technology and production
conformity with all EC Guidelines which affect the drives
available for 60 Hz power systems and other mains voltages
Construction and operation mode
The AViTEQ unbalance motor is a three-phase ac induction motor, on which weights are eccentrically attached at the ends of the running shaft; so-called eccentric weights (flyweights). Centrifugal forces are generated with rotating waves. The value of these centrifugal forces can be changed by adjustment of the flyweights while the motors are at standstill. The centrifugal forces which the motor generates displace the working device (conduit, table, shaped form) and the conveyed material mass by means of vibrations.
With working torques of 0.1 kg.cm to 2,763 kg.cm and centrifugal forces up to 119kN, AViTEQ unbalance motors can move devices of more than 11,000 kg dead weight.
In the case of unbalance motors elliptical, circular or rectilinear vibration movements of the working device can be generated, according to arrangement:
Double drives, which are counterrotating and synchronous rotating, generate a linear vibration movement; for example, in the case of vibration conduits or pipes.
Individual drives, which are arranged at the center of gravity, generate a circular vibration movement; for example in the case of filters.
Individual drives, which are arranged outside of the center of gravity, result in an elliptical vibration movement; for example for the shaking of bunkers.
Aviteq Controller
VIBTRONIC®-controllers are designed to supply AC voltage to control magnetic vibrators. They operate according to the principle of voltage control (phase-fired control). For all standard voltages in the 50 and 60 Hz
main supply, AViTEQ has a suitable controller available in either a built-in or housing design. The controllers have voltage compensation for fluctuations in
the main supply and some models have a limited control that rotects the magnetic vibrator from impact. The setpoint specification
can be set using a potentiometer
or an external setpoint (0-10 VDC or 0/4-20 mA). Information regarding operational status can be read from the integrated status relay and LEDs.
Depending on the model, a vibrator current up to 100 A is possible. Accessories can be used to expand the controllers for use with applications with multiple drives or a vibrating conveyor with reversing operation.
Aviteq Magnetic Vibrator
Magnetic vibrators
Magnetic vibrator
AViTEQ Magnetic vibrators can be used very versatile. The advantages of magnetic vibrators match all designs of vibrating machines. For almost each case of application in the vibration feeder technology and over all industries magnetic vibrators are the favorite system, in particular if it depends on high dosing accuracy. Magnetic vibrators are made in Germany on a highest standard.
Advantages and benefits
easy and continuously adjustable during running conditions
PAL System (protection for wrong amplitudes)
available for 25/33/50/100 (30/40/60/120)Hz variants
immediate start/stop after switching
linear amplitude
Reliable permanent use
High level of performance with compact dimensions
Wear-free, without rotating parts
Efficiency (long operating cycles and service life)
Newest state-of-the-art of production engineering
Conformity with all EC Guidelines, which affect the drives
available for explosion-endangered spaces (Ex)
available for 60 Hz power systems and other mains voltages
Temperature-switch optionally
special versions possible
Accessories:
AViTEQ magnetic vibrators can be variably controlled by the AViTEQ controllers.
Ritter TG0.5/5 Drum-Type Gas meter
Drum-type Gas Meters TG-Series (Wet-Test)
User Benefits
Highest accuracy: ±0,5% across full flow rate range
Calibration traceable to the German National Primary Standard (PTB)
Measurement of all gases and gas mixtures with equal accuracy
Use with extremely corrosive and inert gases
Lowest measurable flow rates
Largest selection of measuring ranges
Real time data acquisition option for PC (requires option »Pulse Generator«)
Most durable construction – available, both chemically (from high-quality thermoplastics) and mechanically (stainless steel)
Maintenance-free (just checking of packing liquid level required)
yokogawa Duplexed Field Control Unit AFV30D-A41262
n GENERAL
This GS covers the hardware specifications of the
Field Control Unit (FCU) which is the core of the
control function of the Field Control Station (FCS).
n STANDARD SPECIFICATIONS
For the installation specifications and the environmental
conditions common to the systems, refer to “Integrated
Production Control System CENTUM VP System
Overview” (GS 33J01A10-01EN).
l Memory Protection During Power Failure
Battery
Battery Back-up for Main Memory: Max. 72 hours
Battery Recharge Time: Min. 48 hours
l READY Contact Output
2 terminals (NC, C)
Contact Points open during FCU failure
Contact Rating: 30 V DC, max. 0.3 A
Note: When option code /HKU is specified, a FCU fault
contact is output from the House Keeping Unit
(HKU).
l Communication Interface
Vnet/IP Interface: Dual-redundant
For more details, refer to "Integrated Prodction
Control Systrm CENTUM VP System Overview" (GS
33J01A10-01EN)
l HKU Interface (Option)
When option code /HKU is specified, a FCU
fault contact is output from the HKU. Also, the
environmental conditions of the cabinet connected via
the HK bus and optical ESB bus can be monitored and
the operating status of the HKU can be displayed on
the HIS. System alarms can also be displayed.
l No. of Node Units Connectable
Max. 13/FCU
The total number of ESB Bus Node Units (ANB10)
and Optical ESB Bus Node Units (ANB11) that can
be connected to FCU are 13 or less.
l Module Configuration
Power Supply Module (PW481, PW482, or PW484):
2 modules for dual-redundant
configuration.
Processor Module (CP471 or CP461):
2 modules for dual-redundant
configuration.
A dual-redundant configuration is enabled
by using 2 identical modules with same
model code (CP471 or CP461).
I/O Module (*1): Max. 8
*1: Non-standard component.
[19-inch Rack Mountable Type FCU]
l Installation Restrictions
To connect the ESB Bus Node Unit (ANB10) or
Optical ESB Bus Node Unit (ANB11) to the FCU,
install the ESB Bus Coupler Module (EC401 or EC402)
in slots 7 and 8 of the FCU. For the dual-redundant
configuration of the processor modules, EC401 or
EC402 must be installed in both slot 7 and slot 8.
In case ESB Bus has a single configuration, EC401
or EC402 must be installed in slot 7 and keep slot 8
empty.
To install the optical ESB bus node unit and ESB bus
node unit in a remote location, use the Optical ESB
Bus Repeater Master Module (ANT401 or ANT411) to
connect them with an optical fiber cable. To install the
optical ESB bus repeater master module in the FCU,
install a pair of modules in slots 1 to 6 in order from
right to left according to the number of branches. In a
single configuration, install the individual modules in
slots 1, 3, and 5 in order from right to left. For details,
see the “Optical ESB Bus Repeater Module”
(GS 33J60F51-01EN/GS 33J60F52-01EN).
For the limitations and precautions for installing I/O
modules, see “FIO System Overview”
(GS 33J60A10-01EN).
l Power Supply
Specify with the Suffix Code.
Voltage: 100-120 V AC, Frequency: 50/60 Hz
Voltage: 220-240 V AC, Frequency: 50/60 Hz
Voltage: 24 V DC
[Release 6]
F01E.ai
Yokogawa UT35A/UT32A Indicating Controller
Yokogawa UT35A and UT32A The Yokogawa UT35A/UT32A are entry-level digital indicating controllers. Available in 1/8 DIN (model UT32A) and 1/4 DIN (model UT35A), these low-cost models have a sequence control function that is based on the general-purpose ladder logic programming language and are targeted for use in the single-loop control of production equipment.
Indicating controllers are embedded in industrial furnaces and other relatively small-scale production line equipment and installations, and are used to measure, display, and control various types of data including temperature, pressure, and flow rate. Indicating controllers typically require complex configuration and programming due to product incompatibility, required peripheral devices and differences in communications protocols. The UT32A and UT35A overcome these limitations by incorporating a ladder sequence function which simplifies creating simple sequence control. Additionally, by adopting open system architecture which complies with Ethernet and PROFIBUS DP protocols, the UT32A and UT35A make it easy to develop multi-vendor systems for users by eliminating the need for dedicated communication programs and/or converters for connecting to devices such as a data-acquisition unit or PLC.
YOKOGAWA ANB10D-410/CU2N NODE INTERFACE UNIT
GENERAL
The ESB Bus Node Unit has an interface function that
communicates the analog I/O signals and contact I/O
signals of a field with a Field Control Unit (FCU) via an
ESB bus, as well as a function that supplies power to
the I/O Modules.
This node units are connected to FCU via an ESB
bus.
n HARDWARE S
l No. of Node Units Connectable
Vnet/IP
Field
Control
Unit
Database
AFV30
AFV40
(*1)
Total Number of ESB Bus Node Units (ANB10) and Optical
ESB Bus Node Units (ANB11) Connected per FCU
Control Function for Field Control Station (LFS1700) Max. 3
Control Function for Field Control Station (LFS1700)
plus Node Expansion Package (LFS1750-V1)
Max. 9
Control Function for Field Control Station (LFS1700)
plus Node Expansion Package (LFS1750-V2)
*1: Up to 11 node units per 1 cabinet can be installed in AFV40.
Field
Control
Unit
Database
ESB Bus Node
Units (ANB10)
Connected per FCU
Max. 13
ER Bus Node
Units (ANR10)
Connected per FCU
AFV10
Control Function for Field Control Station (LFS1500) Max. 3 Max. 3 Max. 3
Vnet
Field
Control
Control Function for Field Control Station (LFS1500)
plus Application Capacity Expansion Package
(LFS1550)
Unit
Database
AFF50
Control Function for Compact Field Control Station
AFG30
AFG40
Total Number of
ESB Bus Node
Units (ANB10)
and ER Bus Node
Units (ANR10)
Connected per FCU
Max. 9 Max. 14 Max. 14
ESB Bus Node
Units (ANB10)
Connected per FCU
ER Bus Node
Units (ANR10)
Connected per FCU
(LFS1350)
Max. 3 Max. 3 Max. 3
Control Function for Enhanced Field Control Station
(LFS1330) with Node expanded databases
Max. 10 Max. 14 Max. 15
Others Max. 10 (*1) Max. 9 (*1) Max. 10 (*1)
*1: In Case of AFG81 and AFG82, there are total number with SIO Nest (for CENTUM V or CENTUM-XL).
Total number of SIO: Max 5/FCU
F01.ai
Total Number of
ESB Bus Node
Units (ANB10)
and ER Bus Node
Units (ANR10)
Connected per FCU
Yokogawa YS1500 Indicating Controller
The YS1500 Indicating Controller incorporates fundamental control functions required for PID control. Necessary functions can be selected in accordance with the user's purpose. The available functions include those functions necessary for input signal processing, such as square root extraction and linear segment conversion, and feed-forward calculation. Single-loop, cascade and selector mode is also available. Standard models are smaller and lighter than earlier series, requiring less space for installation, and are compliant with international safety standards including the CE Mark and FM nonincendive (optional) approvals. For easy replacement of earlier controllers, models requiring the same panel cutout dimensions and depth as those of earlier models are also offered.
Yokogawa Manual Setter for MV
YS1350/YS1360 Manual Setter for SV/MV
Featured product image
The YS1350 is a manual setter that allows for manually outputting setting signals to controllers and the like. The YS1360 is a manual setter that allows for manually outputting operation signals to operation terminals. The YS1350 and YS1360 include as standard an operation mode selector switch [cascade (C) and manual (M)], status input-based operation mode selector function, and operation mode discrimination status output function. The YS1350 and YS1360 offer high reliability thanks to Yokogawa's proprietary technology, user friendliness, and expandability. The basic type conforming to the DIN short case size contributes to space saving for mounting, and complies with standards (CE and FM). For easy replacement of earlier models requiring the same panel cutout dimensions and depth as those of earlier models are also offered.
Endress+Hauser Electromagnetic FLowmeter
Electromagnetic flowmeters
Proven flow measuring technology for all electrically conductive liquids in every industry
Electromagnetic flowmeters have been used throughout industries for more than 60 years. These meters are applicable for all conductive liquids, such as water, acids, alkalis, slurries and many others. Typical applications are monitoring of liquids, filling, dosing and precise measurement in custody transfer. The two million magmeters we’ve sold since 1977 need no maintenance and offer seamless system integration into your processes.
Baker Hughes-Bently Nevada Proximity Sensors, Probes & Transducer Systems
Why Bently Sensors?
More than 60 years ago Don Bently launched his first industrial product: the eddy current proximity sensor. The decades since that achievement have seen the quality and diversity of our proximity sensors evolve to include transducers that detect the presence of acceleration, velocity, and pressure.
Today’s high-performance eddy current proximity sensors deliver continuous condition monitoring information and trip monitored machines when needed to support a proactive maintenance program and machinery diagnostics.
Our industry-leading proximity solutions offer superior performance and interchangeability in harsh environments with full API 670 compliance on applicable options. Here are a few benefits of our proximity sensor systems:
Reduces Costs - When you use our proximity sensors as part of your plant-wide monitoring program, your costs associated with insurance, maintenance, and unscheduled repairs will go down significantly
Increases Revenue - Conversely, when you use our proximity sensors as part of your plant-wide monitoring program, revenue will increase through increased uptime and production quality.
Minimizes Unplanned Outages - You can convert unplanned and costly outages into planned, manageable downtime.
Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402
Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06
Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.
The ZR402G converter is equipped with an LCD touch screen which has various setting displays, a calibration display, oxygen concentration trend display, with easier operation and improvement of display functions. The converter is equipped with various standard functions such as measurement and calculation as well as maintenance functions including self-test. The ZR22G separate-type detector uses a high-reliability zirconia sensor, and its heater assembly can be replaced on site. The detector is mounted, for example, on the wall of a flue and can measure the gases directly. The ZR22S separate-type detector for explosion-proof applications is also available.
Elastec Oil Spill
Oil Spill Absorbent Booms and Pads
Oil spill absorbents are pads and booms that can be quickly deployed for spill response. They work by picking up and retaining the oil. The used absorbents can be safely burned on-site in the Elastec SmartAsh® cyclonic barrel burner. For small spills, absorbents may be used as the sole cleanup method, while for larger spills, they may be used to clean up residual oil that can not be reached by skimmers. Elastec offers several types of oil spill absorbents. We can also provide custom clean up response kits.
Sabtu, 25 April 2020
AEG UPS Protect 4 33
Protect 4 33
Multi purpose high power UPS
The Protect 4 is a highly reliable solution with a very long track record in system availability and use, providing safe and uninterrupted power back-up. It is a compact ready to install unit, with a maximum single unit capacity of up to 600 kVA, ensuring the safe operation of your critical loads. Protect 4 is designed to meet the toughest application requirements and offers high reliability with efficient 12 pulse rectifier technology for sinusoidal input current and for reduced input current harmonic distortion (THDi). The Protect 4 can be used in parallel operation with up to 8 units. This increases the power capacity and allows for even greater safety via N+1 redundancy.
AEG Power Solutions UPS systems assure the permanent availability of all your global applications including oil, gas & petrochemical, power generation, transportation and other infrastructures. The Protect 4 is a highly reliable solution with a very long track record in system availability and use, providing safe and uninterrupted power back-up. It is a compact ready to install unit, with a maximum single unit capacity of up to 600 kVA, ensuring the safe operation of your critical loads. It allows you to benefit from a proven design. The robust and easy to operate UPS has excellent overload capability, superior dynamic response and is easy to maintain. Tailoring to specific requirements is possible due to the high level of customization available. Operational expenditure is optimized with a complete and cost effective life cycle.
Protect 4 - Key Features
Short circuit proof
Intelligent battery charging management
Remote servicing
Redundant fans
Comprehensive service support
Highest operating safety
Optimum efficiency, even in the partial load range
Fully loadable neutral conductor
Integrated logbook function with real-time clock
Conch Three-phase SCR power regulator
CR series SCR power regulator (1φ1W or 1φ2W or 3φ2W or 3φ4W digital type)
CR series SCR power regulator (1φ1W or 1φ2W or 3φ2W or 3φ4W digital type)
CR1: 1φ1W
Rated current: 75A, 100A, 125A, 150A. 180A, 225A, 300A, 380A
CR2: 1φ2W or 3φ2W
Rated current: 35A, 50A, 75A, 100A, 125A, 150A, 180A, 225A, 300A, 380A
CR3: 3φ4W
Rated current: 35A, 50A, 75A, 100A, 125A, 150A, 180A, 225A, 300A, 380A, 450A
Hawe Directional spool valves
Directional spool valves
Directional spool valves are a type of directional valve. They control the direction of movement and the velocity of single and double-acting hydraulic consumers.
The range includes on/off directional spool valves, proportional directional spool valves and valve combinations.
Omni Flow Computer OMNI 3000 - 6000 Series
The OMNI 3000E/6000E flow computer – including an enhancement over the basic OMNI 3000/6000 Series – offers improved security, enhanced software capabilities, and improved auditing and alarm functionality.
With its fast one second power-up recovery, field proven reliability, longevity, and usability, the OMNI 3000E/6000E offers the low total cost of ownership that OMNI is recognized for delivering. The 3000E/6000E exceeds all requirements for data processing, accuracy, and calculation cycle time for all recognized standards bodies, including API, ISO, OIML, and AGA.
When choosing between the OMNI 3000 and OMNI 6000 flow computers
The key question to ask is: How many meter runs do you need? The OMNI 3000 supports up to two meter runs. The OMNI 6000 gives you four. Beyond the number of meter runs, other considerations include:
How many and what types of field equipment inputs and outputs will be connected?
What communications connections will you require?
Will you be measuring hydrocarbon gas or liquid or some other fluid?
Will you measure in metric (SI) or U.S. customary units?
What is your preferred installation style?
The OMNI 3000 is typically used for single-liquid or dual-gas meter-run applications. It accepts two field I/O modules (combo modules). The OMNI 3000 comes with one 12‑channel digital I/O module and one communications module (either serial or Ethernet). For all other applications, you should choose an OMNI 6000.
The OMNI 6000 accepts up to 24 input signals using six field I/O modules (combo modules), including two serial SV modules. It is typically used for up to four meter-run applications. The OMNI 6000 comes with two 12‑channel digital I/O modules and up to three communications modules (either serial or Ethernet, or a mix of both).
Vem Asynchronous motors with squirrel-cage rotor:
Asynchronous motors with squirrel-cage rotor:
Power range 500 – 14,000 kW
Number of poles 2-, 4-, 6-, 8- to 16-pole
Synchronous brushless salient pole motors:
Power range 5,000 – 42,000 kW
Number of poles 4-, 6-, 8- to 36-pole
Voltage range 690 – 13,800 V
Cooling types air/water, air/air
Types IM B3 and IM 7115 and modifications
Bearing Rolling or friction bearings
Frequency Mains and converter operation
Kindly look into making an enquiry regarding deviating versions.
Raychem Elexant 4010i Heat Trace Controller
nVent RAYCHEM Elexant 4010i Series is a range of compact, full-featured, touch screen based, single-point heat-tracing controllers, with ground fault protection. It provides control and monitoring for both freeze protection and process temperature maintenance. Available with either an electromechanical relay (EMR) for use in non hazardous areas, or solid-state relay (SSR) for use in non hazardous and Class I Div. 2 / Zone 2 hazardous locations. Capable of controlling up to 32A at 277 Vac.
CAMERON™-MC-III™-EXP-Flow-Analyzer-2
The state of the art liquid and gas measurement with data logging, and Modbus ® communication in an easy-to-use explosion-resistant totaliser, is no comparable to the NUFLO MC-III EXP explosion-resistant flow totalizer. NUFLO MC-III EXP stores and launches many more records in stream than any other industry explosion-resistant stream.
CAMERON™ MC-III™ EXP Specifications
This powerhouse logs and transfers to your device in less than one minute via Modbus up to 384 regular stream logs, 768 hour logs, and 345 activity logs. Available now as either a stand-alone total or a full explosion resistant (CSA) or a total and flowmeter setup (ATEX / IECEX). Cameron’s NUFLOTM MC-IIITM EXP Flow Analyzer offers cutting edge liquid and gas measurement in an explosion-proof, easy-to-use totaliser, with data logging and Modbus ® connections. The MC-III EXP shows more stream records and launches them faster than any other fluid analyzer in the sector. This center logs and sends logs in less than a minute via Modbus to your server. In dangerous areas and under the toughest conditions in the world, the MC-III EXP is designed to deliver reliable performance.
The MC-III EXP binds the gas or liquid turbine meter or preamplifies it. Users can select a 4 to 20 mA input of frequency, a pulse generator or an improved flow meter to calculate flow and amount for remote devices. The MC-III EXP calibration is as straightforward as the connection of the calibration variable to a flow meter and the choice of measuring units. The tool calculates its own division automatically. The range of full and frequency equipment options allow customers to cater to specific requirements for screens, inputs and outputs. In minutes, the built-in wizard will also lead consumers to reliable results even for the first time.
Cambridge Sensotec Rapidox 3100 Multigas Analyser
Rapidox 3100 Multigas Analyser
Type Measurement
Oxygen Sensor 10E-20ppm-30% zirconia sensor, ±1% accuracy
Other Gas Sensors For other sensors, see the sensor matrix
Temperature Sensor 0-1250°C range Type K thermocouple, ±1°C accuracy
Max Gas Temperature 60°C
Ambient Operating Pressure 900mbar to 1100mbar absolute
Ambient Operating Temperature 5°C to 35°C
Warm-up Time 2-5 minutes at 20°C as standard
Voltage 90-260 VAC, 50/60Hz
Voltage Outputs 0-10V linear, user-programmable
Current Outputs 4-20mA linear, user-programmable
Digital Outputs RS232 (RS485 option available): ModBus-rtu protocol
data streamed on demand
Sample Connections 4mm ID / 6mm OD nipple type
Rectus or Swagelock
Front positioned
Display Four line OLED display
Analyser Dimensions 150mm (H) x 350mm (W) x 263mm (D)
Weight 5kg as standard
Pump Option 0-1 litres per minute, user selectable
Aqutek AFS-20 Fuel Sensor
AFS-20 is designed for indoor use wherever diesel fuel or other hydrocarbon based liquids are stored or pumped
► No tools needed for installation
► An ultra-low power solid state logic device. Measurement voltage is supplied by monitoring instrument, should be less than 24 VDC
► Sensor is waterproof, will not trigger alarm even when it is submerged under water
Weidmuller Fuse terminal blocks
Terminal block bottom section with a fuse insertion carrier
Fuse terminal blocks
Feed through and protect
In some applications it is useful to protect the feed through connection with a separate fuse. Fuse terminal blocks are made up of one terminal block bottom section with a fuse insertion carrier. The fuses vary from pivoting fuse
Asikeco H2S in Crude Oil Analyzer
H2S in Crude Oil Analyzer
Data Sheet / White Papers
H2S in Crude Oil Analyzer
Comparison of H2S in Crude Oil Sampling Technologies
Advantages of Tape Detector for H2S Analysis in Crude Oil
Comparison H2S Measurement Techniques for Crude Oil
Measure H2S in Crude Oil for Quality Control and Transportation Safety - ISA AD 2015
Categories: Environmental, Gas Processing, Hydrogen Sulfide (H2S), Refinery, Liquid Analyzers, Process Analyzers, Measurement, Industry Tag: H2S
Overview Features Applications
Product Overview
With our H2S in crude oil analyzer, the ability to analytically quantify H2S in light, medium & heavy crude oil and condensate is greatly enhanced with the Sample Transfer Stripper (STS) utilizing exclusive ASI Membrane Technologies and rateometric-colorimetric detection technology. This principle of operation is described in various ASTM methods including D4084-82, D4468-85, and D4045-81.
Benefits include:
No false high positives
The only detection method truly specific to H2S only, proven by thousands of applications.
Ultra low-maintenance
Advanced Colorimetric-Rateometric Detector is guaranteed hassle-free for long term “hands-free” operation.
Dependable operation
ASI Membrane Technology eliminates liquid carry-over that plagues the antiquated and problematic headspace sampling systems.
No field calibrations
The analyzer does not require calibrations in the field based on exclusive ASI technologies–even with unexpected process changes, no calibrations are required.
Precise measurement
The only technology capable of precise ultra-low ppb and ppm level analysis.
The effective process for measuring H2S in crude oil involves representatively stripping the H2S vapor from the liquid for precise measurement in the gas phase.
The problematic and complicated “headspace” stripping column, which often suffers from liquid carry-over, is not required for this separation. ASI utilizes the state-of-the-art Sample Transfer Stripper (STS) with exclusive ASI Membrane Technologies to efficiently and reliably separate the H2S from the liquid sample for measurement.
The STS is a very simple device that provides an ultra-clean and dry sample to the detector for analysis. The STS uses 90% fewer parts than the complicated “headspace” stripping column method. This results in radically reduced maintenance requirements when compared to the headspace stripping column method and also enhances analytical reliability. ASI is established as the world-wide leader in H2S in Crude analysis due to the many benefits of this exclusive technology.
The principle of operation is based on a continuous, free-flowing liquid sample into the heated Sample Transfer Stripper (STS) unit which separates the liquids from the H2S gas sample, based in part on Henry’s Law.
H2S free carrier air then sweeps the H2S sample to the H2S specific detector for quantitative analysis in ppb, ppm, or percent levels. The analyzer does not require zero or span field calibrations. The detection technology is based on chemically specific density changes and is the only detection method that is specific only to H2S.
The analyzer holds its calibration even when faced with process changes and does not require calibrations in the field. Optical illumination and detection are integrated for maximum resolution and accuracy. Economic payout is increased because of this automated and continuous process analyzer.
Interesting in learning more? Read the case studies for this analyzer.
Looking for a laboratory analyzer? View our portable H2S in crude oil analyzer.
Patents and Patents Pending based on letters that are available on request.
• Conformity to ASTM Methods
• Specific to H2S Only
• Accurate and Continuous Analysis
• Quantitative Measurement in PPB, PPM & Percent Levels
• Proven Reliability
• Calibrations Not Required
• Fast Response Time
• Awarded ‘Preferred Vendor’ by Saudi Aramco
• Remote & Web based monitoring/control of analyzer
• ATEX and IECEx certificates may be available (added cost)
Safety
Transporting crude oil in truck or vessel can be life threatening to personnel due to unknown levels of hydrogen sulfide contained in the crude. An accident could result in serious injury or death. Other methods to measure H2S include exposing the crude oil to the atmosphere (“Can Test” method, N2 Purge and Trap or lab analysis). The model 205 eliminates health risks of personnel by safely measuring H2S content in a closed loop system, ensuring safety of all operators involved.
Quality Control
Off-spec cargoes and processes incur significant losses due to delays and high costs. “Can Test” method, “Purge and Trap” method and lab analysis are labor intensive, inaccurate and can be dangerous. The model 205 measures H2S 24/7 in real-time, ensuring the most accurate and up-to-date data available to operators. This allows extremely high efficiency ensuring operators meet quality control specifications which saves money. Oftentimes the analyzer pays for itself in only weeks.
Crude Oil Stabilizers / Monitoring for MIC – H2S Cracking
The need to accurately measure H2S in crude is critical to ensure proper product specifications and other purposes. The Model 205 continuously measures H2S to ensure product meets specifications without personnel attendance required or costly lab analysis via inaccurate grab samples.
Corrosion Control
Hydrogen Sulfide is corrosive to pipelines, tanks, FPSO and other holding vessels. The model 205 will accurately measure H2S levels and allows historical data to help treat the H2S before cost intensive measures must be taken.
Condensate
Condensate is a valuable product that is often transported by truck for sales. The 205 is a dependable analyzer used to accurately measure H2S in condensate for quality control and transportation safety.
Controlli Motorzed Global Valve 2FGA25 DN25
PN16 2-way globe valve
DN25, Kvs=10 and flanged connections
Cast iron body and stainless steel plug
Fluid temperature -10/200 °C
The 2FGA series valves are used for the control of fluids belonging to group 2 (water, superheated water, steam) according to the provisions of article 13 of Directive 2014/68/EU (PED) in air conditioning, heating and civil heating systems and industrial and plants and thermal machines of industrial processes; therefore they can not be used as safety valves.
The valve body is made of gray cast iron with a stainless steel plug with an equipercentual characteristic and PN16 flanged connections. Seat and plug in stainless steel AISI 303 and Teflon seals make the valve particularly suitable for the control of aggressive fluids such as saturated or overheated steam.
Valve body
Cast Iron
Plug
Inox
PN
16
T Fluid min[°C]
-10
T Fluid max [°C]
200
Leakage [% Kvs]
0,02
Stroke [mm]
16,5
Valve type
2 way
DN [mm]
25.00
Kvs
10.00
Connection
Flanged
Fluid
Water, Steam
Max Differential Press. [kPa]
600
Connection size
UNI EN 1092-1
Bosch Rexroth Electromechanical Cylinder
The electromechanical cylinders from Rexroth are a high-performance alternative to pneumatic and hydraulic cylinders and are scoring top marks when it comes to energy efficiency.
They are taking advantage of the benefits of modern control technology, even at high forces. Parameters for force, position and travel speed can be set as required by the user and flexibly adapted to new tasks at any time via the drive system.
Unimeasure FX-HM series linear position transducer
FX Series
The FX-HM series linear position transducer provides up to 15” (381mm) of measurement range in a subcompact plastic package. With a two point mounting system and a diameter of 1.5 inches, it is ideal for use in areas where space is a premium. The device employs a non-contacting hall effect internal sensor which permits use in applications where a very high cycle life is required. With an excitation voltage requirement anywhere in the range of 4.9 to 30 volts and a very low current requirement, the unit may easily be battery powered or operated from most standard instrumentation power supplies. The analog voltage output of nominally 0 to 10 VDC may be easily interfaced to most popular data acquisition, PLC and display devices. The FX-HM with a dynamic response capability up to 25 Hz over a 1.5” range makes it acceptable for use in measurement applications for suspension travel, throttle position, machine mechanism monitoring and many other applications where space restrictions exist.
Ari Armaturen Zedox Valve
ZEDOX – the double offset high performance valve with metallic sealing
Reliability, even for application with high requirements
Long life thanks to reduced contact pressure between the disc and the metal sealing ring (only minimal frictional pressure)
High energy efficiency due to flow-optimised mounted valve disc
Longer service life due to protection of the seat ring against negative flow influences
Perfect handling due to low torques
Design EN 12516, PED, API 609
Type of connection EN 1092, ASME 16.5, ASME 16.47, GOST
Butt-weld ends DIN EN 12627, ASME B16.25, GOST
Nominal diameter
Double flanged: DN 200-1200, 8“ up to 48“
Wafer type version: DN 80-800, 3“ up to 32“
Butt-weld ends: DN 200-1600 / 8“ up to 64“
Nominal pressure PN 10 bis PN 40, Class 150
Material Cast steel (1.0619 +N; SA216 WCB)
Stainless steel (1.4408; SA351CF8M)
other materials incl. ASTM on request
Temperature -40°C up to +260°C (max. +400°C)
Flow media Liquids, gases, vapours
Actuators anual gearbox, pneumatic, electric, hydraulic drives
YUDEN-TECH CO., LTD. - Taiwan Dew Point Transmitter
eYc THS88 Plus Industrial Grade High Pressure Dew Point Transmitter
Model : eYc THS88 Plus
Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT 100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp °C
Linear accuracy : ±2 dp °C
Max. Scaling range : Dew point : -100 ... +60dp℃
Johnson Control Smoke and Carbon Monoxide Detection Solutions
Benefits of Smoke and Carbon Monoxide Detection
Our innovative software and electronics means we can offer stable smoke and carbon monoxide detectors with the quickest response time and less nuisance. A dirty detector can set off an unwanted alarm—the predictive ability of our remote diagnostics is invaluable by alerting us that the device needs proactive service. Additionally, the addressability of our devices offers time-saving benefits to contractors, facility managers, and owners. Our patented TrueAlarm sensors are one of the industry’s most stable line of detection devices available, and our addressable modules can provide addressability to conventional devices.
As an added benefit, carbon monoxide (CO) sensors can be included in our smoke detectors, saving the expense of a separate purchase as well as reducing wiring needs. Our solutions are especially critical for facilities where people sleep: dormitories, hotels, nursing homes, and assisted living facilities.
Additional Benefits:
Quick detection of fire, smoke, or heat events, allowing orderly evacuation and mitigation of potential fire damage
Solutions are tailored to your facility and integrated with fire suppression systems where needed
Internet-based diagnostic service offers real-time visibility and automates the detection and notification of abnormal conditions
Alerts when detectors are dirty or almost dirty and more vulnerable to problems
Sensors evaluate environmental data and compensate for contamination to maintain detector sensitivity and decrease the chance of false alarms
CO elements can operate independently or in combination with a smoke or heat sensor, helping reduce unnecessary alarms
Ampac Portable Emergency Seawater Desalination Watermaker SW150
In the case of Natural Disasters or wars or for small boats, The Ampac USA Portable Emergency Sea Water Desalination System is a very simple watermaker to use and does not need any skills to operate. This Advanced Portable Watermaker is designed to convert Sea water to Pure Drinking Water within seconds with just a push of a button. This Watermaker will also purify Well Water or Surface Water and convert it to Potable Drinking Water Standards set by the World Health Organization. The Ampac Portable Emergency Seawater Desalination Watermaker can be designed to operate using DC or AC Power as per customer requirement.
Key Features:
AC or DC power as per order
Durable Waterproof Pelican Case
One Button Start-Stop Operation
Energy Efficient, low amperage per gallon of product water
Quiet Operation.
System Pumps Included:
Smart-on Demand Supply pump.
Exclusive high-efficiency booster pump for extended pre-filter life.
Noise Reduction Features:
Noise Pulsation Dampener Included
Smooth running and extraordinarily quiet.
Vibration isolation mounts included.
Materials:
Stainless steel exterior and interior pressure gauges for accurate measurement of watermaker functions.
Fiberglass Reinforced High-Pressure Membrane Vessel is stronger and eliminates corrosion.
Convoluted foam lines the lid; cut foam cubes line the bottom. Cases have double-throw latches, a molded plastic handle, and a hole to accommodate a padlock, with the addition of two 2" Dia. polyurethane wheels and a retractable handle for easy mobility.
Safety:
A failsafe Product Water Diversion Valve
Unique Low Voltage Control Circuitry, shielded terminals, & covered high voltage components for end-user safety.
High rejection / high yield membrane element that produces higher quality product water in a smaller space.
Service & Maintenance:
Shipped from the factory ready to install and function.
There are no optional items required, and a complete installation kit is also included along with a comprehensive and detailed Owner's Operation & Maintenance Manual.
Worldwide Service and Sales Network for immediate attention regardless of location.
Technical service dedicated to excellent system performance.
System Features:
Stage 1: Five-micron Sediment pre-filter that reduces sediment, sand, silt, and rust particles that may be in your water supply.
Stage 2: A heavy duty Five Micron lead and the chemical reducing carbon block filter (LVOC). This specially formulated block is capable of reducing lead as well as harmful Volatile Organic Chemicals. These water contaminants come from a variety of sources including localized use of herbicides and pesticides, gasoline or oil spill.
Stage 3: Improved FILMTEC™ seawater reverse osmosis elements offer the highest productivity while maintaining excellent salt rejection.FILMTEC SW membrane elements have the highest flow rates available to meet the water demands of both sea-based and land-based desalinators. FILMTEC SW elements operate at lower pressure to reduce cost and operating expenses.
Improved FILMTEC seawater membrane combined with automated, precision element fabrication result in the most consistent product performance available.
Stage 4: Extruded activated carbon filter consist of virgin activated carbon powder, a thermoplastic binder, and specialty adsorbents such as zeolites oxidizing filtration media. The filters are manufactured as continuous lengths of rod, tube, slab, flexible flat sheet, or as other complex shapes using a proprietary solid-state extrusion process. The resulting products are highly porous and extremely uniform, providing high-performance adsorption and particulate reduction at low flow resistance when fabricated into finished filter elements.
Extruded activated carbon filters meet exacting performance requirements and/or claims, and specific models are registered as meeting the requirements of NSF/ANSI for VOCs and THMs reduction, particulate, cyst, turbidity, lead reduction, chlorine taste and odor reduction, and other requirements relating to purity and safety of their materials of construction.
Stage 5: Ultraviolet disinfection is a means of killing or rendering harmless microorganisms in a dedicated environment. These microorganisms can range from bacteria and viruses to algae and protozoa. Ultra Violet disinfection is used to disinfect and sterilize Permeate Product Water after the Desalination Process. A major advantage of UV treatment is that it is capable of disinfecting water faster than chlorine without cumbersome retention tanks and harmful chemicals. UV treatment systems are also extremely cost efficient!
Benefits:
The Ampac USA Portable Emergency Sea Water Desalination Watermaker is ideal for any military, UN, Red Cross units or rescue operation on the field.
This Unit can use solar energy, Car Battery or Marine Battery to power up, transforming Seawater, Surface Water or dirty water into safe pure drinking water within seconds.
This Sea Water Desalination Watermaker comes with all Pre-Filtration, R/O Process and Post-Filtration in one single Durable Enclosure capable of producing 150 GPD.
If you are looking for a Reliable and Durable Sea Water Desalinator for Emergency or Portable Applications, this is your Ultimate Watermaker.
This Unit can be used on Land or on Your boat.
Demonstration Video:
Ampac USA Portable Emergency Sea Water Desalination Watermaker
The Ampac Emergency Portable Sea Water Desalination Water Maker is the next generation system designed for Portable Marine, Navy Applications with internal High-Pressure Booster Pump for ease of use in compact locations. Featuring a simple interface, the SeaPro Plus™ can be monitored via the control panel or the on-deck Remote Control. All components within the frame are readily accessible for easy maintenance.
Production Based on the Following Feed water Conditions
Water TDS < 50,000 ppm
Recovery 30%
Rejection 98% Average
Water temperature 25º Celsius
Pressure
> 10 psi
DC or AC 110V/220V/380V/460V 50Hz/60Hz Single or 3 Phase power
Production over a 24-Hour Period
*Prices are subject to change without notice.
Langganan: