
Kami adalah agen tunggal untuk alat industri merk Kansai Automation dari Jepang dan Cambridge Sensotec Gas Analyzer dari Inggris. Selain itu, kami adalah importir umum semua alat industri disesuaikan dengan kebutuhan end user. Hubungi kami di syukur1970@gmail.com
Penayangan bulan lalu
Minggu, 26 April 2020
Protocontrol Flameproof Model Belt Sway Switch

Walchem WCT/WDT400 Cooling Tower Controllers

Torontech Vicat Apparatus

Gilson Asphalt Electric Core Drill

ABM VAN ZIJL VICAMATIC 2 automatic vicat apparatus

Besmak Vicat Apparatus

Fitok Pressure Gauge GA-63-NS4-4000PB
Frer Earth Leakage Relay

Thermo Fisher Scientific High Performance Benchtop Centrifuges
Choose from a growing family of benchtop centrifuges designed to meet the needs of your specific applications. With careful attention to your space, process and protocol requirements, we continue to innovate our line of centrifuges that stand out for their performance, reliability, consistency and safety. Whether performing clinical protocols, cell culture procedures, microplate processing, or anything in between, Thermo Scientific centrifuges fulfill a variety of separation needs.
Ideal for research or controlled environments, our high performance benchtop centrifuges meet customers' needs for application flexibility and high speeds. They come in medium 1.6L and large 4L sizes with touch screen options and floor/portable options, offering a high performing drive with an advanced touch screen interface designed for maximum protocol versatility, complementing the numerous rotor configurations available.
Get unparalleled processing performance, maximum versatility, and exceptional energy efficiency with our high performance benchtop centrifuges.

Clark-Reliance Corporation - Anderson® - Centrifugal Separators

BOECO Autoclave BTE-23D

Wess Global Ultrasonic Sludge Density Meter (ENV200S)

Koehler Instruments KV3000 and KV4000 Constant Temperature Kinematic Viscosity Baths

Shanghai Boqu DWS-51A Laboratory Sodium Meter

Bante Instruments - 931 Benchtop Sodium Ion Meter

Scimatco SC5060 Polypropylene Acid Cabinet

Aviteq Handling Technology

Aviteq Conveyor Belt

Aviteq UV Motor

Aviteq Controller

Aviteq Magnetic Vibrator
Magnetic vibrators
Magnetic vibrator
AViTEQ Magnetic vibrators can be used very versatile. The advantages of magnetic vibrators match all designs of vibrating machines. For almost each case of application in the vibration feeder technology and over all industries magnetic vibrators are the favorite system, in particular if it depends on high dosing accuracy. Magnetic vibrators are made in Germany on a highest standard.
Advantages and benefits
easy and continuously adjustable during running conditions
PAL System (protection for wrong amplitudes)
available for 25/33/50/100 (30/40/60/120)Hz variants
immediate start/stop after switching
linear amplitude
Reliable permanent use
High level of performance with compact dimensions
Wear-free, without rotating parts
Efficiency (long operating cycles and service life)
Newest state-of-the-art of production engineering
Conformity with all EC Guidelines, which affect the drives
available for explosion-endangered spaces (Ex)
available for 60 Hz power systems and other mains voltages
Temperature-switch optionally
special versions possible
Accessories:
AViTEQ magnetic vibrators can be variably controlled by the AViTEQ controllers.

Ritter TG0.5/5 Drum-Type Gas meter

yokogawa Duplexed Field Control Unit AFV30D-A41262
n GENERAL
This GS covers the hardware specifications of the
Field Control Unit (FCU) which is the core of the
control function of the Field Control Station (FCS).
n STANDARD SPECIFICATIONS
For the installation specifications and the environmental
conditions common to the systems, refer to “Integrated
Production Control System CENTUM VP System
Overview” (GS 33J01A10-01EN).
l Memory Protection During Power Failure
Battery
Battery Back-up for Main Memory: Max. 72 hours
Battery Recharge Time: Min. 48 hours
l READY Contact Output
2 terminals (NC, C)
Contact Points open during FCU failure
Contact Rating: 30 V DC, max. 0.3 A
Note: When option code /HKU is specified, a FCU fault
contact is output from the House Keeping Unit
(HKU).
l Communication Interface
Vnet/IP Interface: Dual-redundant
For more details, refer to "Integrated Prodction
Control Systrm CENTUM VP System Overview" (GS
33J01A10-01EN)
l HKU Interface (Option)
When option code /HKU is specified, a FCU
fault contact is output from the HKU. Also, the
environmental conditions of the cabinet connected via
the HK bus and optical ESB bus can be monitored and
the operating status of the HKU can be displayed on
the HIS. System alarms can also be displayed.
l No. of Node Units Connectable
Max. 13/FCU
The total number of ESB Bus Node Units (ANB10)
and Optical ESB Bus Node Units (ANB11) that can
be connected to FCU are 13 or less.
l Module Configuration
Power Supply Module (PW481, PW482, or PW484):
2 modules for dual-redundant
configuration.
Processor Module (CP471 or CP461):
2 modules for dual-redundant
configuration.
A dual-redundant configuration is enabled
by using 2 identical modules with same
model code (CP471 or CP461).
I/O Module (*1): Max. 8
*1: Non-standard component.
[19-inch Rack Mountable Type FCU]
l Installation Restrictions
To connect the ESB Bus Node Unit (ANB10) or
Optical ESB Bus Node Unit (ANB11) to the FCU,
install the ESB Bus Coupler Module (EC401 or EC402)
in slots 7 and 8 of the FCU. For the dual-redundant
configuration of the processor modules, EC401 or
EC402 must be installed in both slot 7 and slot 8.
In case ESB Bus has a single configuration, EC401
or EC402 must be installed in slot 7 and keep slot 8
empty.
To install the optical ESB bus node unit and ESB bus
node unit in a remote location, use the Optical ESB
Bus Repeater Master Module (ANT401 or ANT411) to
connect them with an optical fiber cable. To install the
optical ESB bus repeater master module in the FCU,
install a pair of modules in slots 1 to 6 in order from
right to left according to the number of branches. In a
single configuration, install the individual modules in
slots 1, 3, and 5 in order from right to left. For details,
see the “Optical ESB Bus Repeater Module”
(GS 33J60F51-01EN/GS 33J60F52-01EN).
For the limitations and precautions for installing I/O
modules, see “FIO System Overview”
(GS 33J60A10-01EN).
l Power Supply
Specify with the Suffix Code.
Voltage: 100-120 V AC, Frequency: 50/60 Hz
Voltage: 220-240 V AC, Frequency: 50/60 Hz
Voltage: 24 V DC
[Release 6]
F01E.ai

Yokogawa UT35A/UT32A Indicating Controller

YOKOGAWA ANB10D-410/CU2N NODE INTERFACE UNIT
GENERAL
The ESB Bus Node Unit has an interface function that
communicates the analog I/O signals and contact I/O
signals of a field with a Field Control Unit (FCU) via an
ESB bus, as well as a function that supplies power to
the I/O Modules.
This node units are connected to FCU via an ESB
bus.
n HARDWARE S
l No. of Node Units Connectable
Vnet/IP
Field
Control
Unit
Database
AFV30
AFV40
(*1)
Total Number of ESB Bus Node Units (ANB10) and Optical
ESB Bus Node Units (ANB11) Connected per FCU
Control Function for Field Control Station (LFS1700) Max. 3
Control Function for Field Control Station (LFS1700)
plus Node Expansion Package (LFS1750-V1)
Max. 9
Control Function for Field Control Station (LFS1700)
plus Node Expansion Package (LFS1750-V2)
*1: Up to 11 node units per 1 cabinet can be installed in AFV40.
Field
Control
Unit
Database
ESB Bus Node
Units (ANB10)
Connected per FCU
Max. 13
ER Bus Node
Units (ANR10)
Connected per FCU
AFV10
Control Function for Field Control Station (LFS1500) Max. 3 Max. 3 Max. 3
Vnet
Field
Control
Control Function for Field Control Station (LFS1500)
plus Application Capacity Expansion Package
(LFS1550)
Unit
Database
AFF50
Control Function for Compact Field Control Station
AFG30
AFG40
Total Number of
ESB Bus Node
Units (ANB10)
and ER Bus Node
Units (ANR10)
Connected per FCU
Max. 9 Max. 14 Max. 14
ESB Bus Node
Units (ANB10)
Connected per FCU
ER Bus Node
Units (ANR10)
Connected per FCU
(LFS1350)
Max. 3 Max. 3 Max. 3
Control Function for Enhanced Field Control Station
(LFS1330) with Node expanded databases
Max. 10 Max. 14 Max. 15
Others Max. 10 (*1) Max. 9 (*1) Max. 10 (*1)
*1: In Case of AFG81 and AFG82, there are total number with SIO Nest (for CENTUM V or CENTUM-XL).
Total number of SIO: Max 5/FCU
F01.ai
Total Number of
ESB Bus Node
Units (ANB10)
and ER Bus Node
Units (ANR10)
Connected per FCU

Yokogawa YS1500 Indicating Controller
The YS1500 Indicating Controller incorporates fundamental control functions required for PID control. Necessary functions can be selected in accordance with the user's purpose. The available functions include those functions necessary for input signal processing, such as square root extraction and linear segment conversion, and feed-forward calculation. Single-loop, cascade and selector mode is also available. Standard models are smaller and lighter than earlier series, requiring less space for installation, and are compliant with international safety standards including the CE Mark and FM nonincendive (optional) approvals. For easy replacement of earlier controllers, models requiring the same panel cutout dimensions and depth as those of earlier models are also offered.

Yokogawa Manual Setter for MV
YS1350/YS1360 Manual Setter for SV/MV
Featured product image
The YS1350 is a manual setter that allows for manually outputting setting signals to controllers and the like. The YS1360 is a manual setter that allows for manually outputting operation signals to operation terminals. The YS1350 and YS1360 include as standard an operation mode selector switch [cascade (C) and manual (M)], status input-based operation mode selector function, and operation mode discrimination status output function. The YS1350 and YS1360 offer high reliability thanks to Yokogawa's proprietary technology, user friendliness, and expandability. The basic type conforming to the DIN short case size contributes to space saving for mounting, and complies with standards (CE and FM). For easy replacement of earlier models requiring the same panel cutout dimensions and depth as those of earlier models are also offered.

Endress+Hauser Electromagnetic FLowmeter

Baker Hughes-Bently Nevada Proximity Sensors, Probes & Transducer Systems

Yokogawa Single Channel Oxygen Analyzer System ZR22/ZR402

Elastec Oil Spill
Oil Spill Absorbent Booms and Pads
Oil spill absorbents are pads and booms that can be quickly deployed for spill response. They work by picking up and retaining the oil. The used absorbents can be safely burned on-site in the Elastec SmartAsh® cyclonic barrel burner. For small spills, absorbents may be used as the sole cleanup method, while for larger spills, they may be used to clean up residual oil that can not be reached by skimmers. Elastec offers several types of oil spill absorbents. We can also provide custom clean up response kits.

Sabtu, 25 April 2020
AEG UPS Protect 4 33

Conch Three-phase SCR power regulator

Hawe Directional spool valves

Omni Flow Computer OMNI 3000 - 6000 Series

Vem Asynchronous motors with squirrel-cage rotor:

Raychem Elexant 4010i Heat Trace Controller

CAMERON™-MC-III™-EXP-Flow-Analyzer-2

Cambridge Sensotec Rapidox 3100 Multigas Analyser

Aqutek AFS-20 Fuel Sensor

Weidmuller Fuse terminal blocks

Asikeco H2S in Crude Oil Analyzer

Controlli Motorzed Global Valve 2FGA25 DN25

Bosch Rexroth Electromechanical Cylinder

Unimeasure FX-HM series linear position transducer

Ari Armaturen Zedox Valve
ZEDOX – the double offset high performance valve with metallic sealing
Reliability, even for application with high requirements
Long life thanks to reduced contact pressure between the disc and the metal sealing ring (only minimal frictional pressure)
High energy efficiency due to flow-optimised mounted valve disc
Longer service life due to protection of the seat ring against negative flow influences
Perfect handling due to low torques
Design EN 12516, PED, API 609
Type of connection EN 1092, ASME 16.5, ASME 16.47, GOST
Butt-weld ends DIN EN 12627, ASME B16.25, GOST
Nominal diameter
Double flanged: DN 200-1200, 8“ up to 48“
Wafer type version: DN 80-800, 3“ up to 32“
Butt-weld ends: DN 200-1600 / 8“ up to 64“
Nominal pressure PN 10 bis PN 40, Class 150
Material Cast steel (1.0619 +N; SA216 WCB)
Stainless steel (1.4408; SA351CF8M)
other materials incl. ASTM on request
Temperature -40°C up to +260°C (max. +400°C)
Flow media Liquids, gases, vapours
Actuators anual gearbox, pneumatic, electric, hydraulic drives
YUDEN-TECH CO., LTD. - Taiwan Dew Point Transmitter
eYc THS88 Plus Industrial Grade High Pressure Dew Point Transmitter
Model : eYc THS88 Plus
Features :Speed Upgrade 150%
Input : Capacitive humidity sensor & PT 100 Ω
Output : Standard RS-485 & 1 analog output
Pressure resistance : 16 bar
Working range of dew point : -60 ... +60 dp °C
Linear accuracy : ±2 dp °C
Max. Scaling range : Dew point : -100 ... +60dp℃
Johnson Control Smoke and Carbon Monoxide Detection Solutions
Benefits of Smoke and Carbon Monoxide Detection
Our innovative software and electronics means we can offer stable smoke and carbon monoxide detectors with the quickest response time and less nuisance. A dirty detector can set off an unwanted alarm—the predictive ability of our remote diagnostics is invaluable by alerting us that the device needs proactive service. Additionally, the addressability of our devices offers time-saving benefits to contractors, facility managers, and owners. Our patented TrueAlarm sensors are one of the industry’s most stable line of detection devices available, and our addressable modules can provide addressability to conventional devices.
As an added benefit, carbon monoxide (CO) sensors can be included in our smoke detectors, saving the expense of a separate purchase as well as reducing wiring needs. Our solutions are especially critical for facilities where people sleep: dormitories, hotels, nursing homes, and assisted living facilities.
Additional Benefits:
Quick detection of fire, smoke, or heat events, allowing orderly evacuation and mitigation of potential fire damage
Solutions are tailored to your facility and integrated with fire suppression systems where needed
Internet-based diagnostic service offers real-time visibility and automates the detection and notification of abnormal conditions
Alerts when detectors are dirty or almost dirty and more vulnerable to problems
Sensors evaluate environmental data and compensate for contamination to maintain detector sensitivity and decrease the chance of false alarms
CO elements can operate independently or in combination with a smoke or heat sensor, helping reduce unnecessary alarms
Ampac Portable Emergency Seawater Desalination Watermaker SW150
In the case of Natural Disasters or wars or for small boats, The Ampac USA Portable Emergency Sea Water Desalination System is a very simple watermaker to use and does not need any skills to operate. This Advanced Portable Watermaker is designed to convert Sea water to Pure Drinking Water within seconds with just a push of a button. This Watermaker will also purify Well Water or Surface Water and convert it to Potable Drinking Water Standards set by the World Health Organization. The Ampac Portable Emergency Seawater Desalination Watermaker can be designed to operate using DC or AC Power as per customer requirement.
Key Features:
AC or DC power as per order
Durable Waterproof Pelican Case
One Button Start-Stop Operation
Energy Efficient, low amperage per gallon of product water
Quiet Operation.
System Pumps Included:
Smart-on Demand Supply pump.
Exclusive high-efficiency booster pump for extended pre-filter life.
Noise Reduction Features:
Noise Pulsation Dampener Included
Smooth running and extraordinarily quiet.
Vibration isolation mounts included.
Materials:
Stainless steel exterior and interior pressure gauges for accurate measurement of watermaker functions.
Fiberglass Reinforced High-Pressure Membrane Vessel is stronger and eliminates corrosion.
Convoluted foam lines the lid; cut foam cubes line the bottom. Cases have double-throw latches, a molded plastic handle, and a hole to accommodate a padlock, with the addition of two 2" Dia. polyurethane wheels and a retractable handle for easy mobility.
Safety:
A failsafe Product Water Diversion Valve
Unique Low Voltage Control Circuitry, shielded terminals, & covered high voltage components for end-user safety.
High rejection / high yield membrane element that produces higher quality product water in a smaller space.
Service & Maintenance:
Shipped from the factory ready to install and function.
There are no optional items required, and a complete installation kit is also included along with a comprehensive and detailed Owner's Operation & Maintenance Manual.
Worldwide Service and Sales Network for immediate attention regardless of location.
Technical service dedicated to excellent system performance.
System Features:
Stage 1: Five-micron Sediment pre-filter that reduces sediment, sand, silt, and rust particles that may be in your water supply.
Stage 2: A heavy duty Five Micron lead and the chemical reducing carbon block filter (LVOC). This specially formulated block is capable of reducing lead as well as harmful Volatile Organic Chemicals. These water contaminants come from a variety of sources including localized use of herbicides and pesticides, gasoline or oil spill.
Stage 3: Improved FILMTEC™ seawater reverse osmosis elements offer the highest productivity while maintaining excellent salt rejection.FILMTEC SW membrane elements have the highest flow rates available to meet the water demands of both sea-based and land-based desalinators. FILMTEC SW elements operate at lower pressure to reduce cost and operating expenses.
Improved FILMTEC seawater membrane combined with automated, precision element fabrication result in the most consistent product performance available.
Stage 4: Extruded activated carbon filter consist of virgin activated carbon powder, a thermoplastic binder, and specialty adsorbents such as zeolites oxidizing filtration media. The filters are manufactured as continuous lengths of rod, tube, slab, flexible flat sheet, or as other complex shapes using a proprietary solid-state extrusion process. The resulting products are highly porous and extremely uniform, providing high-performance adsorption and particulate reduction at low flow resistance when fabricated into finished filter elements.
Extruded activated carbon filters meet exacting performance requirements and/or claims, and specific models are registered as meeting the requirements of NSF/ANSI for VOCs and THMs reduction, particulate, cyst, turbidity, lead reduction, chlorine taste and odor reduction, and other requirements relating to purity and safety of their materials of construction.
Stage 5: Ultraviolet disinfection is a means of killing or rendering harmless microorganisms in a dedicated environment. These microorganisms can range from bacteria and viruses to algae and protozoa. Ultra Violet disinfection is used to disinfect and sterilize Permeate Product Water after the Desalination Process. A major advantage of UV treatment is that it is capable of disinfecting water faster than chlorine without cumbersome retention tanks and harmful chemicals. UV treatment systems are also extremely cost efficient!
Benefits:
The Ampac USA Portable Emergency Sea Water Desalination Watermaker is ideal for any military, UN, Red Cross units or rescue operation on the field.
This Unit can use solar energy, Car Battery or Marine Battery to power up, transforming Seawater, Surface Water or dirty water into safe pure drinking water within seconds.
This Sea Water Desalination Watermaker comes with all Pre-Filtration, R/O Process and Post-Filtration in one single Durable Enclosure capable of producing 150 GPD.
If you are looking for a Reliable and Durable Sea Water Desalinator for Emergency or Portable Applications, this is your Ultimate Watermaker.
This Unit can be used on Land or on Your boat.
Demonstration Video:
Ampac USA Portable Emergency Sea Water Desalination Watermaker
The Ampac Emergency Portable Sea Water Desalination Water Maker is the next generation system designed for Portable Marine, Navy Applications with internal High-Pressure Booster Pump for ease of use in compact locations. Featuring a simple interface, the SeaPro Plus™ can be monitored via the control panel or the on-deck Remote Control. All components within the frame are readily accessible for easy maintenance.
Production Based on the Following Feed water Conditions
Water TDS < 50,000 ppm
Recovery 30%
Rejection 98% Average
Water temperature 25º Celsius
Pressure
> 10 psi
DC or AC 110V/220V/380V/460V 50Hz/60Hz Single or 3 Phase power
Production over a 24-Hour Period
*Prices are subject to change without notice.
Langganan:
Postingan (Atom)